YASKAWA GA800 Technical Reference page 766

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

12.3 b: Application
b8-24: PM E-Save High Freq ACR Gain
No.
Name
(Hex.)
b8-24
PM E-Save High Freq ACR
Gain
(0B45)
Expert
Note:
If the drive detects oC [Overcurrent], decrease the value.
b8-25: PM E-Save Search Start Level
No.
Name
(Hex.)
b8-25
PM E-Save Search Start
Level
(0B46)
Expert
Note:
If there is vibration in the machine, increase the value.
b8-26: PM E-Save Power Setpoint
No.
Name
(Hex.)
b8-26
PM E-Save Power Setpoint
(0B47)
Expert
b8-28: Over Excitation Action Selection
No.
Name
(Hex.)
b8-28
Over Excitation Action
Selection
(0B8B)
Expert
When operation is not stable at low speeds, set this parameter to 1 to enable the function.
0 : Disabled
1 : Enabled
b8-29: Energy Saving Priority Selection
No.
Name
(Hex.)
b8-29
Energy Saving Priority
Selection
(0B8C)
Enable this parameter when there are small changes in the load. It is possible that the motor cannot respond correctly
to changes in the load.
0 : Priority: Drive Response
1 : Priority: Energy Savings
b8-50: Standby Mode Selection
No.
Name
(Hex.)
b8-50
Standby Mode Selection
(0B0D)
766
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for high-frequency current control.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the start level for search operations.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a value to increase torque accuracy.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for excitation operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the priority of drive response between changes to the load or Energy-saving control. Enable this
to prioritize energy-saving control. Disable this to prioritize tracking related to fast load changes, and
prevent motor stall.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Standby Mode function.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Default
(Range)
200.0 Hz
(100.0 - 1000.0 Hz)
Default
(Range)
10.0%
(0.0 - 100.0%)
Default
(Range)
0.0%
(-10.0 - +10.0%)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)

Advertisement