OFF : External torque reference forward direction
7A: KEB Ride-Thru 2 Activate (N.C.)
Setting Value
Function
7A
KEB Ride-Thru 2 Activate
(N.C.)
ON : Normal operation
OFF : Deceleration during momentary power loss
When KEB Ride-Thru 2 is input, the drive will use Single Drive KEB Ride-Thru 2 for KEB operation. The L2-29
[KEB Method Selection] setting will not have an effect.
Note:
• If you set KEB Ride-Thru 1 [H1-xx = 65, 66] and KEB Ride-Thru 2 [H1-xx = 7A, 7B] at the same time, the drive will detect oPE03 [Multi-
Function Input Setting Err].
• Refer to
KEB Ride-Thru Function on page 964
7B: KEB Ride-Thru 2 Activate (N.O.)
Setting Value
Function
7B
KEB Ride-Thru 2 Activate
(N.O.)
ON : Deceleration during momentary power loss
OFF : Normal operation
When KEB Ride-Thru 2 is input, the drive will use Single Drive KEB Ride-Thru 2 for KEB operation. The L2-29
[KEB Method Selection] setting will not have an effect.
Note:
• If you set KEB Ride-Thru 1 [H1-xx = 65, 66] and KEB Ride-Thru 2 [H1-xx = 7A, 7B] at the same time, the drive will detect oPE03 [Multi-
Function Input Setting Err].
• Refer to
KEB Ride-Thru Function on page 964
7C: Short Circuit Braking (N.O.)
Setting Value
Function
7C
Short Circuit Braking (N.O.)
The drive will short circuit the three phases of a PM motor to cause braking torque in the spinning motor.
Note:
• When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
• Refer to
b2: DC Injection Braking and Short Circuit Braking on page 729
ON : Short Circuit Braking is enabled.
OFF : Normal operation
7D: Short Circuit Braking (N.C.)
Setting Value
Function
7D
Short Circuit Braking (N.C.)
The drive will short circuit the three phases of a PM motor to cause braking torque in the spinning motor.
Note:
• When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
• Refer to
b2: DC Injection Braking and Short Circuit Braking on page 729
ON : Normal operation
OFF : Short Circuit Braking is enabled.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.C.).
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.O.).
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.O.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.C.).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
for more information.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
for more information.