YASKAWA GA800 Technical Reference page 583

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
F7-41
Dynamic In Param 9 for
CommCard
(037D)
F7-42
Dynamic In Param 10 for
CommCard
(037E)
F7-60
PZD1 Write (Control
Word)
(0780)
F7-61
PZD2 Write (Frequency
Reference)
(0781)
F7-62
PZD3 Write
(0782)
F7-63
PZD4 Write
(0783)
F7-64
PZD5 Write
(0784)
F7-65
PZD6 Write
(0785)
F7-66
PZD7 Write
(0786)
F7-67
PZD8 Write
(0787)
F7-68
PZD9 Write
(0788)
F7-69
PZD10 Write
(0789)
F7-70
PZD1 Read (Status Word)
(078A)
F7-71
PZD2 Read (Output
Frequency)
(078B)
F7-72
PZD3 Read
(078C)
F7-73
PZD4 Read
(078D)
F7-74
PZD5 Read
(078E)
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values
from the MEMOBUS/Modbus address registers stored for each parameter to Input
Assembly 166. The drive returns the default register value for the option card when the
MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values
from the MEMOBUS/Modbus address registers stored for each parameter to Input
Assembly 166. The drive returns the default register value for the option card when the
MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, set the MEMOBUS/Modbus address for PZD1 (PPO
output). PZD1 (PPO output) functions as the STW when F7-60 = 0 to 2.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO
output). PZD2 (PPO output) functions as the HSW when F7-61 = 0 to 2.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO
output). A value of 0, 1, or 2 will disable the PZD3 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO
output). A value of 0, 1, or 2 will disable the PZD4 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO
output). A value of 0, 1, or 2 will disable the PZD5 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO
output). A value of 0, 1, or 2 will disable the PZD6 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO
output). A value of 0, 1, or 2 will disable the PZD7 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO
output). A value of 0, 1, or 2 will disable the PZD8 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO
output). A value of 0, 1, or 2 will disable the PZD9 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO
output). A value of 0, 1, or 2 will disable the PZD10 (PPO output) write operation to the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD1 (PPO
input). PZD1 (PPO input) functions as the ZSW when F7-70 = 0.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO
input). PZD2 (PPO input) functions as the HIW when F7-71 = 0.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO
input). A value of 0 will disable the PZD3 (PPO input) load operation from the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO
input). A value of 0 will disable the PZD4 (PPO input) load operation from the
MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO
input). A value of 0 will disable the PZD5 (PPO input) load operation from the
MEMOBUS/Modbus register.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.9 F: Options
Default
Ref.
(Range)
0
878
0
878
0
878
0
878
0
878
0
878
0
878
0
879
0
879
0
879
0
879
0
879
0
879
0
879
0
880
0
880
0
880
583