Output Function Parameters - Delta VFD-EL-W Series Manual

Sensorless vector control compact drive
Hide thumbs Also See for VFD-EL-W Series:
Table of Contents

Advertisement

Chapter 4 Parameters|VFD-EL-W

03 Output Function Parameters

Pr.
Parameter Name
03.00 Multi-Function Output Relay
03.01 Reserved
Desired Frequency
03.02
Reached
03.03 Reserved
03.04 Reserved
03.05 Count Value Reached
Preliminary Count Value
03.06
Reached
EF Activates when the
03.07
Terminal Count Value
Reached
 You can set this parameter during operation.
Setting Range
0: No function
1: Indication during RUN
2: Master frequency reached
3: Indication at zero speed
4: Over-torque detection
5: Base Block (B.B) indication
6: Low-voltage indication
7: Operation mode indication
8: Fault indication
9: Desired frequency reached
10: Terminal count value reached
11: Preliminary count value reached
12: Over-voltage stall prevention
13: Over-current stall prevention
14: IGBT overheating (85°C ON, 80°C OFF)
15: Over-voltage
16: PID feedback error
17: Forward command
18: Reverse command
19: Zero speed (including STOP)
20: Warning indication
21: Mechanical brake control (use with Pr.03.11 and
Pr.03.12)
22: Drive is ready
23: Indication of multi-pump system error (only
Master)
0.00–400.0 Hz
0–9999
0–9999
0: Terminal count value reached, no EF displays
1: Terminal count value reached, EF activates
46
Default
8
0.00
0
0
0