Initialize HFSI Counters

Purpose
Initialize the HFSI Counter.
Procedure
Reading and resetting HFSI
1.
Access Diagnostic Routines.
a.
Enter UI Diagnostics
(UI Diagnostic
Chain-Link
Name
954-807
Last 2Digits of Fuser discharging Number
954-807
5th&6thDigits of Fuser discharging Number
954-807
3rd&4thDigits of Fuser discharging Number
954-807
First 2Digits of Fuser discharging Number
954-800
Tray1 Last 2Digits of Feed Capacity (8 Digits)
954-800
Tray1 5th&6thDigits of Feed Capacity (8 Digits)
954-800
Tray1 3rd&4thDigits of Feed Capacity (8 Digits)
954-800
Tray1 First 2Digits of Feed Capacity (8 Digits)
954-801
Tray2 Last 2Digits of Feed Capacity (8 Digits)
954-801
Tray2 5th&6thDigits of Feed Capacity (8 Digits)
954-801
Tray2 3rd&4thDigits of Feed Capacity (8 Digits)
954-801
Tray2 First 2Digits of Feed Capacity (8 Digits)
954-802
Tray3 Last 2Digits of Feed Capacity (8 Digits)
954-802
Tray3 5th&6thDigits of Feed Capacity (8 Digits)
954-802
Tray3 3rd&4thDigits of Feed Capacity (8 Digits)
954-802
Tray3 First 2Digits of Feed Capacity (8 Digits)
954-803
Tray4 Last 2Digits of Feed Capacity (8 Digits)
Launch Version
WorkCentre 5225, 5230
Mode).
Initial
Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2.
Select Adjustment/Other.
3.
Select HFSI Counter.
4.
Reset Correct Value
a.
Enter the Chain-Link Number
b.
Select Reset Correct Value. Diagnostics routine completed will be displayed
NOTE: Diagnostics routine completed will be displayed. The HFSI Counter is reset.
HFSI
Table 1 IOT HFSI
Value
1Count Remarks
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~3
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~3
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~3
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~3
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
0~99
1
Only 0 clearance is possible in the write mode.("0 clearance" means all bytes
changes 0 at the same time.)
February, 2008
6-115
General Procedures
Initialize HFSI Counters