dC132 Serial Number/Billing Meter Synchronization

Purpose
Checks the Billing Meters and sets the Machine Serial Number when fault 103-208 occurs.
This routine also reads the Billing Meters and can be accessed at any time for this purpose.
Procedure
Failure to comply with the board replacement procedure in
could result in catastrophic NVM corruption.
Follow the procedure described in
GP 10 Replacing Billing
Prelaunch Training/Review
DC1632/2240
CAUTION
GP 10 Replacing Billing
PWBs.

dC135 HFSI Counters

Purpose
This routine displays the service life (Threshold) and the current value (count) of the periodic
replacement parts. Replacement life change, and current value resets are possible.
Procedure
1.
Enter the Diagnostic Mode. Refer to
2.
Select Maintenance on the Service Entry Screen. The All Jams screen displays as the
PWBs,
default screen.
3.
Select HFSI Counters (dC135) tab on the Maintenance screen.
4.
The HFSI Counters screen displays the replacement life (Threshold) and the current
value (count) of the periodic replacement parts. Two vertical tabs allow display of all HFSI
counters, or only those counters that are over threshold.
5.
Refer to
Detailed Maintenance Activities
all HSFI counters that are at or near threshold.
6.
To reset the count after replacing the parts, select the appropriate HFSI item, then select
the Reset Counter button.