Condition Data Setting Examples - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

10.4.2 Condition data setting examples

The following shows the setting examples for "condition data".
(1) QD77MS2/QD77MS4
(a) Setting the device ON/OFF as a condition
[Condition]
Device "XC" (Axis 1 BUSY signal) is OFF.
[Da.15]
Condition target
01H: Device X
(b) Setting the numeric value stored in the "buffer memory" as a condition
[Condition]
The value stored in buffer memory addresses "800, 801" ("[Md.20] Current
feed value") is "1000" or larger.
[Da.15]
Condition target
04H: Buffer memory
(2 words)
(c) Designating the axis and positioning data No. to be simultaneously started in
"simultaneous start"
[Condition]
Simultaneously starting "axis 2 positioning data No.3"
[Da.15]
Condition target
05H: Positioning
data No.
(Note-1): The setting value of start axis (the axis which executes positioning start) should
be "0000H".
Chapter 10 High-Level Positioning Control
[Da.16]
[Da.17]
Condition
Address
operator
08H: DEV=OFF
[Da.16]
[Da.17]
Condition
Address
operator
 P1
04H:
800
[Da.16]
[Da.17]
Condition
Address
operator
20H: Axis 2
selected
10 - 19
[Da.18]
[Da.19]
Parameter 1
Parameter 2
0CH
[Da.18]
[Da.19]
Parameter 1
Parameter 2
1000
[Da.18]
[Da.19]
Parameter 1
Parameter 2
High-order 16
(Note-1)
bits "0003H"
(Note-1)