Mitsubishi Electric QD77MS User Manual page 926

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Classification
Error
Error name
of errors
code
Manual pulse
generator/Incremental
976
synchronous encoder
input type selection
error
Operation setting for
977
speed-torque control
mode error
External command
978
signal selection error
Parameter
Synchronous encoder
setting range
979
via servo amplifier
errors
invalid error
980
OPR method error
981
OPR direction error
OP address setting
982
error
983
OPR speed error
Error
The set value of the detailed parameter 2
"Manual pulse generator/Incremental
synchronous encoder input type selection"
is outside the setting range.
The set value of the detailed parameter 2
"Operation setting for speed-torque control
mode" is outside the setting range.
The set value of the detailed parameter 2
"External command signal selection" is
outside the setting range.
• The servo amplifier axis set as
synchronous encoder via servo amplifier
is not supported with scale measurement
mode.
• In system construction, the unset up
servo amplifier axis is set as the
synchronous encoder via servo amplifier.
• In system construction, the axis set to
"Invalid" at the external synchronization
encoder input is set as the synchronous
encoder via servo amplifier.
• The servo amplifier axis set as
synchronous encoder via servo amplifier
is connected to the linear scale.
The set value of the OPR basic parameter
"OPR method" is outside the setting range.
The set value of the OPR basic parameter
"OPR direction" is outside the setting
range.
The set value of the OPR basic parameter
"OP address" is outside the setting range.
• The set value of the OPR basic
parameter "OPR speed" is outside the
setting range.
• The set value of the OPR basic
parameter "OPR speed" is smaller than
the bias speed at start.
16 - 46
Chapter 16 Troubleshooting
Operation status at error occurrence
The READY signal [X0] is not turned ON.