Thank you for purchasing the safety programmable controller,
MELSEC-QS series. The MELSEC-QS programmable controller is
suitable for establishing safety functions for general industrial
machinery.
Prior to use, please read both this manual and detailed manual
thoroughly to fully understand the product.
© 2006 MITSUBISHI ELECTRIC CORPORATION
CC-Link Safety System
MODEL QS0J61BT12-U-HW
MODEL
CODE
IB(NA)-0800344-I(1806)MEE
Master Module
User's Manual
(Hardware)
QS0J61BT12
13JP95

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric QS0J61BT12

  • Page 1 MELSEC-QS series. The MELSEC-QS programmable controller is suitable for establishing safety functions for general industrial machinery. Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product. MODEL QS0J61BT12-U-HW MODEL 13JP95 CODE IB(NA)-0800344-I(1806)MEE © 2006 MITSUBISHI ELECTRIC CORPORATION...
  • Page 2 SAFETY PRECAUTIONS (Read these precautions before using this product.) Before using this product, please read the Safety Guidelines included with the base unit. Also, please read this manual, the relevant manuals, the manuals for standard programmable controllers, and the relevant safety standards carefully, and pay full attention to safety to handle the product correctly.
  • Page 3 CONDITIONS OF USE FOR THE PRODUCT (1) Although MELCO has obtained the certification for Product's compliance to the international safety standards IEC61508, ISO13849-1 from TUV Rheinland, this fact does not guarantee that Product will be free from any malfunction or failure. The user of this Product shall comply with any and all applicable safety standard, regulation or law and take appropriate safety measures for the system in which the Product is installed or used and shall take the second or third safety measures other than the Product.
  • Page 4 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 5: Table Of Contents

    CONTENTS 1. OVERVIEW ....................1 1.1 Compatibility with CC-Link ............... 1 1.2 Safety Programmable Controller Product List ......... 1 2. SPECIFICATIONS ..................2 2.1 Performance Specifications ..............2 2.2 Maximum Overall Cable Distance ............3 2.3 CC-Link Dedicated Cable Specifications ..........3 2.4 Safety Standards ..................
  • Page 6 Detailed Manual Manual No. Manual name (Model code) CC-Link Safety System Master Module User's Manual SH-080600ENG QS0J61BT12 (13JR88) COMPLIANCE WITH THE EMC, LOW VOLTAGE, AND MACHINERY DIRECTIVES (1) Method of ensuring compliance To ensure that Mitsubishi programmable controllers maintain EMC,...
  • Page 7: Overview

    1. OVERVIEW This manual describes the specifications, part names, and settings of the QS0J61BT12 CC-Link Safety system master module (hereinafter referred to as the QS0J61BT12), which is used with the MELSEC-QS series programmable controller CPUs. After unpacking, confirm that the following items are enclosed.
  • Page 8: Specifications

    2. SPECIFICATIONS 2.1 Performance Specifications Table 2.1 shows the performance specifications of the QS0J61BT12. Refer to the User’s Manual of the CPU for the general specifications of the QS0J61BT12. Table 2.1 Performance specifications Item Specifications Transmission rate Select from 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps...
  • Page 9: Maximum Overall Cable Distance

    Table 2.1 Performance specifications Item Specifications Recommended connection cable Version 1.10 compatible CC-Link dedicated cable * Câble de connexion Câble dédié CC-Link compatible Ver.1.10 * recommandé No. of I/O occupied points 32 points (I/O assignment: 32 intelligent points) 5V DC internal current 0.46A consumption Weight...
  • Page 10: Safety Standards

    2.4 Safety Standards Normes de sécurité Use the product according to the following safety standards. Region Safety Standards IEC61508 Parts 1-7:1998-2000, ISO13849-1:2015, International IEC61131-2:2007, IEC61000-6-2:2005, IEC61000-6-4:2006, IEC61784-3:2010, IEC60204-1:2009 EN ISO13849-1:2015, EN61131-2:2007, Europe EN61000-6-2:2005, EN61000-6-4:2007 North America UL508, NFPA79:2015 Utiliser le produit dans le respect des normes de sécurité suivantes. Région Normes de sécurité...
  • Page 11: Mounting And Installation

    3. MOUNTING AND INSTALLATION 3.1 Handling Precautions The handling precautions for the module are given below. (1) Since the module case is made of resin, do not drop it or apply strong impacts on it. (2) Do not remove the PCB of each module from its case. This may cause a failure in the module.
  • Page 12: Installation Environment

    Improper installation may result in malfunction, failure, or drop of the module. POINT (1) Always turn the power of the corresponding station OFF before mounting or removing the terminal block. If it is mounted or removed without turning OFF the power, correct data transmission by the mounted or removed station will not be guaranteed.
  • Page 13: Part Names And Settings

    4. PART NAMES AND SETTINGS...
  • Page 14 This is a 2-piece terminal block, and the module can be replaced without disconnecting the signal wires connected to the terminal block. (Replace the module after turning its power OFF.) (FG) Serial number plate Indicates the serial number of the QS0J61BT12.
  • Page 15: External Wiring

    CC-Link dedicated cable (Ver.1.00) 1/2 W CC-Link dedicated high-performance cable (brown-orange-brown) * This resisters are provided with QS0J61BT12 (4) The safety master module can be connected to any location other than both ends. (5) Star topology is not allowed. (6) A connection method is shown below.
  • Page 16 English French Safety master module Module maître de sécurité Remote module Module distant Terminating resistor Résistance d'extrémité CC-Link dedicated cable Câble dédié pour CC-Link Blue Bleu White Blanc Yellow Jaune IMPORTANT Each of the CC-Link dedicated cables (for Ver.1.10, Ver.1.00, and high-performance cables) cannot be used together with another type of cable.
  • Page 17: Extermal Dimensions

    6. EXTERMAL DIMENSIONS 1:NC 2:NC 3:DA 4:SLD 5:DB 6:(FG) 7:DG 27.4 Unit: mm...
  • Page 18: Ec Declaration Of Conformity For Machinery Directive

    7. EC DECLARATION OF CONFORMITY FOR MACHINERY DIRECTIVE...
  • Page 20 MEMO...
  • Page 21 MEMO...
  • Page 22 Please confirm the following product warranty details before using this product. 1. Limited Warranty and Product Support. a. Mitsubishi Electric Company ("MELCO") warrants that for a period of eighteen (18) months after date of delivery from the point of manufacture or one year from date of Customer's purchase, whichever is less, Mitsubishi MELSEC Safety programmable logic controllers (the "Products") will be free from defects in material and workmanship.
  • Page 23 2. Limits of Warranties. a. MELCO does not warrant or guarantee the design, specify, manufacture, construction or installation of the materials, construction criteria, functionality, use, properties or other characteristics of the equipment, systems, or production lines into which the Products may be incorporated, including any safety, fail-safe and shut down systems using the Products.
  • Page 24 3. Limits on Damages. a. MELCO'S MAXIMUM CUMULATIVE LIABILITY BASED ON ANY CLAIMS FOR BREACH OF WARRANTY OR CONTRACT, NEGLIGENCE, STRICT TORT LIABILITY OR OTHER THEORIES OF RECOVERY REGARDING THE SALE, REPAIR, REPLACEMENT, DELIVERY, PERFORMANCE, CONDITION, SUITABILITY, COMPLIANCE, OR OTHER ASPECTS OF THE PRODUCTS OR THEIR SALE, INSTALLATION OR USE SHALL BE LIMITED TO THE PRICE PAID FOR PRODUCTS NOT AS WARRANTED.
  • Page 25 4. Delivery/Force Majeure. a. Any delivery date for the Products acknowledged by MELCO is an estimated and not a promised date. MELCO will make all reasonable efforts to meet the delivery schedule set forth in Customer's order or the purchase contract but shall not be liable for failure to do b.
  • Page 26 20 Waterford Office Park, 189 Witkoppen Road, Avenida Adelino Cardana, 293, 21 andar, Fourways, South Africa Bethaville, Barueri SP, Brazil Tel : +27-11-658-8100 Tel : +55-11-4689-3000 Germany MITSUBISHI ELECTRIC EUROPE B.V. German China MITSUBISHI ELECTRIC AUTOMATION (CHINA) Branch LTD. Mitsubishi-Electric-Platz 1, 40882 Ratingen, No.1386 Hongqiao Road, Mitsubishi Electric...