List Of Monitor Data - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

5.6 List of monitor data

The setting items of the monitor data are explained in this section.
• Guide to buffer memory address
In the buffer memory address, "n" in "2406+100n", etc. indicates a value
corresponding to axis No. such as the following table.
(Note-1): Calculate as follows for the buffer memory address corresponding to each axis.
(Note-2): The range from axis No.1 to 2 (n=0 to 1) is valid in the QD77MS2.
(Note-3): The range from axis No.1 to 4 (n=0 to 3) is valid in the QD77MS4.
5.6.1 System monitor data
Storage item
[Md.1] In test mode flag
Axis No.
n
Axis No.
1
0
5
2
1
6
3
2
7
4
3
8
(Example) For axis No. 16
2406+100n ([Md.23] Axis error No.)=2406+100 15=3906
Whether the mode is the test mode from the GX Works2 or not is stored.
When not in test mode : OFF
When in test mode
Refresh cycle: Immediate
5 - 114
Chapter 5 Data Used for Positioning Control
n
Axis No.
n
Axis No.
4
9
8
13
5
10
9
14
6
11
10
15
7
12
11
16
Storage details
: ON
n
12
13
14
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents