Appendix 1 List Of Buffer Memory Addresses - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Appendix 1 List of buffer memory addresses

Buffer memory address
QD77MS2
QD77MS16
QD77MS4
0+150n
1+150n
2+150n
3+150n
4+150n
5+150n
6+150n
7+150n
10+150n
11+150n
12+150n
13+150n
14+150n
15+150n
The following shows the relation between the buffer memory addresses and the
various items.
(Note-1): Do not use the buffer memory address that not been described here for a
"Maker setting".
(Note-2): For the list of buffer memory addresses for positioning data, refer to the
"Simple Motion Module Setting Tool Help" of GX Works2.
(Note-3): For the list of buffer memory addresses used in synchronous control, refer to
the "MELSEC-Q/L QD77MS/QD77GF/LD77MS/LD77MH Simple Motion
Module User's Manual (Synchronous Control)".
(Note-4): Guide to buffer memory address
•In the buffer memory address, "n" in "1+150n", etc. indicates a value
corresponding to axis No.
Calculate as follows for the buffer memory address corresponding to each
axis.
(Example) For axis No. 16
•In the buffer memory address, "p" in "4012+5p", etc. indicates a pointer No.
Calculate as follows for the buffer memory address corresponding to each
pointer No.
(Example) For pointer No. 15
Compatibility
of setting value
of QD77MS2/
QD77MS4 and
QD77MS16
[Pr.1] Unit setting
[Pr.4] Unit magnification (AM)
[Pr.2] Number of pulses per rotation (AP)
[Pr.3] Movement amount per rotation (AL)
[Pr.7] Bias speed at start
[Pr.8] Speed limit value
[Pr.9] Acceleration time 0
[Pr.10] Deceleration time 0
1+150n ([Pr.4] Unit magnification (AM))=1+150 15=2251
4012+5p ([Md.3] Start information)=4012+5 15=4087
: Compatible
Appendix - 2
Item
: Partly compatible
Appendices
Memory
area
n: Axis No.-1
: Not compatible

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents