Mitsubishi Electric QD77MS User Manual page 344

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

(b) When the circuit uses the "intelligent function device" on the source(s) side
and the destination (D) side of a MOV command, change the command to a
FROM command and a TO command.
X15
X0C
0
X15
X0C
0
(c) When the circuit uses the "intelligent function device" for a COMPARISON
command, change the command to a FROM command and a
COMPARISON command.
M0
U0\
0
=
G1521
M0
0
=
D102
(d) When the circuit uses the "intelligent function device" for a WAND command,
change the command to a FROM command and a WAND command.
M2
0
M2
0
Chapter 6 Sequence Program Used for Positioning Control
K0
Data read out
K0
6 - 4
U0\
MOVP
G826
FROMP
H0
K826
D100
TOP
H6
K1
D100
RST
FROMP
H0
K1521
D102
RST
U0\
WANDP
G817
H8
FROMP
H0
K817
D101
Data read out
WANDP
D101
H8
U6\
G1
Set the
same device.
K1
K1
M0
K1
M0
D0
K1
D0