Mitsubishi Electric QD77MS User Manual page 127

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Forcibly removal the SSCNET
Motion module and SSCNET
After removal of the SSCNET
Otherwise, adhesion of dirt deteriorates in characteristic and it may cause malfunctions.
Do not remove the SSCNET
module and servo amplifier. Do not see directly the light generated from SSCNET
and the end of SSCNET
eye. (The light source of SSCNET
IEC60825-1.)
If the SSCNET
cable is added a power such as a major shock, lateral pressure, haul, sudden
bending or twist, its inside distorts or breaks, and optical transmission will not be available.
Be sure to take care enough so that the short SSCNET
Be sure to use the SSCNET
manual. Especially, as optical fiber for MR-J3BUS_M and MR-J3BUS_M-A are made of
synthetic resin, it melts down if being left near the fire or high temperature. Therefore, do not
make it touched the part which becomes high temperature, such as radiator or regenerative
option of servo amplifier, or servomotor.
When laying the SSCNET
(Refer to this Section [2] Precautions for SSCNET
Put the SSCNET
cable in the duct or fix the cable at the closest part to the Simple Motion
module with bundle material in order to prevent SSCNET
on SSCNET
connector. When laying cable, the optical cord should be given loose slack to
avoid from becoming smaller than the minimum bend radius, and it should not be twisted.
Also, fix and hold it in position with using cushioning such as sponge or rubber which does not
contain plasticizing material.
Migrating plasticizer is used for vinyl tape. Keep the MR-J3BUS_M, and MR-J3BUS_M-A
cables away from vinyl tape because the optical characteristic may be affected.
SSCNET
cable
MR-J3BUS_M
MR-J3BUS_M-A
MR-J3BUS_M-B
: Normally, cable is not affected by plasticizer.
: Phthalate ester plasticizer such as DBP and DOP may affect optical characteristic of cable.
Generally, soft polyvinyl chloride (PVC), polyethylene resin (PE) and fluorine resin contain non-
migrating plasticizer and they do not affect the optical characteristic of SSCNET
However, some wire sheaths and cable ties, which contain migrating plasticizer (phthalate
ester), may affect MR-J3BUS_M and MR-J3BUS_M-A cables (made of plastic).
In addition, MR-J3BUS_M-B cable (made of quartz glass) is not affected by plasticizer.
Chapter 4 Installation, Wiring and Maintenance of the Product
CAUTION
cable from the Simple Motion module will damage the Simple
cables.
cable, be sure to put a cap on the SSCNET
cable while turning on the power supply of Simple Motion
cable. When the light gets into eye, may feel something is wrong for
cable complies with class1 defined in JISC6802 or
cable within the range of operating temperature described in this
cable, be sure to secure the minimum cable bend radius or more.
Optical cord
Cord
4 - 9
cable is added a twist easily.
cable wiring.)
cable from putting its own weight
Cable
Cable
connector.
connector
cable.