(4) I/O signals of slave axis

(a) Input signal
[QD77MS2]
Only the error detection signal [X8, X9] is valid. And only the servo
alarm detection is valid. (The control of slave axis is not influenced even
if the error other than servo alarm has been occurred.)
[QD77MS4]
Only the error detection signal [X8 to XB] is valid. And only the servo
alarm detection is valid. (The control of slave axis is not influenced even
if the error other than servo alarm has been occurred.)
[QD77MS16]
All signals cannot be used. The error detection signal turns ON "Error
detection" ([Md.31]
(b) Output signal
All output signals of slave axis cannot be used.

(5) Data used for positioning control of slave axis

(a) Only the following axis monitor data are valid in slave axis.
Item
[Md.23]
Axis error No.
Torque limit stored value/forward
[Md.35]
torque limit stored value
[Md.102]
Deviation counter value
[Md.103]
Motor rotation speed
[Md.104]
Motor current value
[Md.107]
Parameter error No.
[Md.108]
Servo status
Regenerative load ratio/Optional
[Md.109]
data monitor output 1
Effective load torque/Optional
[Md.110]
data monitor output 2
Peak torque ratio/Optional data
[Md.111]
monitor output 3
[Md.112]
Optional data monitor output 4
[Md.114]
Servo alarm
[Md.120]
Reverse torque limit stored value
: b13).
Status
Valid for only servo alarm detection.
The following bit is valid.
• b0: Zero point pass
The following bits are valid.
• b0: READY ON
• b1: Servo ON
• b7: Servo alarm
(Note): The slave axis is always
14 - 36
Chapter 14 Common Functions
Remark
(Execute OPR to the master axis.)
controlled in torque control mode,
"control mode (high-order buffer
memory address: b2, b3)" is set
to torque control mode (0, 1).