Mitsubishi Electric QD77MS User Manual page 241

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Item
Value set with GX Works2
0 : End
[Da.11]
Shape
1 : Continue
Positioning data No.:
[Da.12]
1 to 600
Start data No.
(01H to 258H)
0 : Block start (normal start)
1 : Condition start
2 : Wait start
[Da.13]
Special start
3 : Simultaneous start
instruction
4 : FOR loop
5 : FOR condition
6 : NEXT start
Condition data No.:
[Da.14]
1 to 10 (01H to 0AH)
Parameter
Number of repetitions:
0 to 255 (00H to FFH)
Chapter 5 Data Used for Positioning Control
Setting value
Value set with sequence program
0
b15
b11
b7
0 0 0
1
Shape
01H
to
Start data No.
258H
00H
01H
b15
b11
b7
02H
03H
04H
05H
Special start
instruction
06H
00H
to
FFH
Parameter
5 - 103
Buffer memory address
Default
QD77MS2
value
QD77MS4
b3
b0
0000
26000+1000n 22000+400n
H
b3
b0
0000
26050+1000n 22050+400n
H
QD77MS16
n: Axis No.-1

Hide quick links: