Related buffer memory address
QD77MS2
QD77MS16
QD77MS4
30100+200n
28400+100n
30100+200n
28400+100n
147
105
78+150n
74+150n
75+150n
80+150n
81+150n
74+150n
75+150n
1500+100n
4300+100n
1500+100n
4300+100n
Set range
(Setting with sequence program)
<Servo series>
0, 1, 3, 4, 6, 7, 32, 48, 64, 96, 97, 98, 99
<Servo series>
97
<OPR retry>
0, 1
<OPR speed>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min or others]
<Movement amount setting after near-
point dog ON>
0 to 2147483647
<OPR speed>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min]
<Positioning start No.>
1 to 600, 7000 to 7004, 9001 to 9004
<Positioning start No.>
1 to 600, 7000 to 7004, 9001 to 9004
16 - 19
Chapter 16 Troubleshooting
Remedy
Turn ON the PLC READY signal [Y0] with the BUSY signals
of all axes OFF.
Do not request the start when the axis operation state is other
than "standby", "stop", and "step standby".
Match the set series of the servo parameter "[Pr.100] Servo
series" to the series of connected servo amplifier.
Connect supported servo amplifier/driver.
Review the content of the positioning or "[Pr.96] Operation
cycle setting" longer than the current setting.
• Validate the OPR retry function (set value: 1). (Refer to
Section 13.2.1).
• Move the work piece from the current position (on OP) using
the manual control operation (refer to Chapter 11), then carry
out a machine OPR again.
• Lower the OPR speed.
• Increase the dog signal input time.
(Refer to Section 8.2.3)
• Calculate the movement distance using a speed limit, OPR
speed, and deceleration time, and set the movement amount
after near-point dog ON so that the distance becomes a
deceleration distance or longer.
• Lower the OPR speed.
• Adjust the near-point dog position so that the movement
amount after near-point dog ON becomes longer. (Refer to
Section 8.2.4, 8.2.5)
Execute the machine OPR (positioning start No. 9001). (Refer
to Section 8.2)
Start the machine OPR (positioning start No. 9001) again.
(Refer to Section 8.2)
Turn the motor more than one revolution using JOG or
positioning operation.
• Execute OPR again.
• When the servo parameter "Function selection C-4 (PC17)"
is changed to "1: Not need to pass servo motor Z-phase after
power on", transfer the parameter from the Simple Motion
module to the servo amplifier and turn the power supply of
the servo amplifier OFF. Then, turn it ON and execute OPR
again.