Appendix 6.2 Inverter FR-A700 series

FR-A700 series can be connected via SSCNET
and FR-A7NS.
The details shown below explain about the "Connection with FR-A700 series".
[1] Connecting method
[2] Comparisons of specifications with MR-J3(W)-B
[3] Precautions during control
[4] FR-A700 series detection error/warning
[1] Connecting method
(1) System configuration
The system configuration using FR-A700 series is shown below.
Set "0: SSCNET " in "[Pr.97] SSCNET setting" to use FR-A700 series.
Simple Motion module
SSCNET
cable
MR-J3BUS_M(-A/-B)
(2) Parameter setting
To connect FR-A700 series, execute flash ROM writing after setting the
following parameters to buffer memory. The setting value is valid when the
power supply is turned ON or the PLC CPU is reset.
"[Pr.97] SSCNET setting": "0: SSCNET "
"[Pr.100] Servo series" : "64: FR-A700 series (Inverter)"
SSCNET
Appendix - 73
by using built-in option FR-A7AP
Inverter
FR-A700 series
QD77MS2 : Up to 2 axes
QD77MS4 : Up to 4 axes
QD77MS16: Up to 16 axes
Appendices
Servo amplifier
MR-J3(W)-B