Mitsubishi Electric QD77MS User Manual page 929

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Related buffer memory address
QD77MS2
QD77MS16
QD77MS4
76+150n
77+150n
78+150n
80+150n
81+150n
82+150n
83+150n
86+150n
88+150n
87+150n
147
105
106
Set range
(Setting with sequence program)
<Creep speed>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min or others]
0, 1
0 to 2147483647
0, 1, 2, 3
0, 1, 2, 3
1 to 1000
0, 1
0, 1
0, 1
<SSCNET setting>
0, 1
<Servo series>
0, 1, 3, 4, 6, 7, 32, 48,64,96, 4097, 4128
16 - 49
Chapter 16 Troubleshooting
Remedy
• Bring the setting into the setting range.
• Set the speed to that below the OPR speed.
• Set the value to the bias speed at start or higher.
(Refer to Section 5.2.5)
With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
With the setting brought into the setting range, write to the
flash ROM and switch the power on again or reset the PLC.
With "SSCNET setting" and "Servo series" set by a correct
combination, write to the flash ROM and switch the power on
again or reset the PLC.
n: Axis No.-1