Mitsubishi Electric QD77MS User Manual page 307

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Set with a decimal.
Setting value
K
1
After the M code ON signal turns OFF, "0" is stored by the Simple Motion
module automatically. (Indicates that the OFF request is completed.)
Set with a decimal.
Setting value
K
Set with a decimal.
Actual value
Cd.9 New current value
Conversion into an integer value
10
Setting value
R
(Decimal)
Set with a decimal.
Cd.10 New acceleration time value
Setting
value
Cd.11 New deceleration time value
Example: When the " Cd. 10 New acceleration
time value" is set as "60000 ms", the
buffer memory stores "60000".
Setting value
M code OFF request
1: M code ON signal turns OFF
External command valid
0: Invalidates an external command.
1: Validates an external command.
Unit conversion table ( Cd.9 )
m
m
1
5
5
0
5 - 169
Chapter 5 Data Used for Positioning Control
Buffer memory address
Default
value
QD77MS2
QD77MS4
0
1504+100n
0
1505+100n
1506+100n
0
1507+100n
Unit
m
inch
degree
PLS
1508+100n
0
1509+100n
1510+100n
0
1511+100n
QD77MS16
4304+100n
4305+100n
4306+100n
4307+100n
4308+100n
4309+100n
4310+100n
4311+100n
n: Axis No.-1