Mitsubishi Electric QD77MS User Manual page 772

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

2
1
Teaching arc end point
address on axis 2.
NO
End teaching?
Turn OFF the PLC READY
signal [Y0].
Carry out a writing request to
the flash ROM.
Confirm the completion of the writing.
End
[Motion path]
(Axis 2)
Forward direction
Reverse direction
OP
Reverse direction
*1: The sub point address is stored in the arc address.
*2: The end point address is stored in the positioning address.
[5] Teaching program example
• • • • • • • •
YES
• • • • • • • •
• • • • • • • •
*1 Sub point address
(arc address)
Start point address
(current stop position)
The following shows a sequence program example for setting (writing) the
positioning data obtained with the teaching function to the Simple Motion module.
(1) Setting conditions
When setting the current feed value as the positioning address, write it
when the BUSY signal is OFF.
(2) Program example
The following example shows a program to carry out the teaching of axis
1 by the dedicated instruction "ZP.TEACH 1".
1)
Move the workpiece to the target position using a JOG operation (or
an inching operation, a manual pulse generator operation).
Entering teaching data to buffer memory address
[1648] and [1649], in the same fashion as for axis 1.
Set 1 in the buffer memory address [1900].
Confirm that the buffer memory address [1900] has become 0.
Movement by circular interpolation
*2 End point address
(positioning address)
Arc center point
Forward direction
(Axis 1)
13 - 84
Chapter 13 Control Sub Functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents