Name
[Cd.40] ABS direction in degrees
POINT
(1) When the upper/lower limit value of the axis which set the software stroke limit
as valid are changed, perform the machine OPR after that.
(2) When the software stroke limit is set as valid in the incremental data system,
perform the machine OPR after power supply on.

[3] Positioning control method when the control unit is set to "degree"

1) Absolute system
(a) When the software stroke limit is invalid
Positioning is carried out in the nearest direction to the designated
address, using the current value as a reference.
(This is called "shortcut control".)
Example
1) Positioning is carried out in a clockwise direction when the current value is moved from 315° to 45°.
2) Positioning is carried out in a counterclockwise direction when the current value is moved from 45° to 315°.
1) Moved from 315° to 45°
315°
To designate the positioning direction (not carrying out the shortcut control), the
shortcut control is invalidated and positioning in a designated direction is carried out by
the "[Cd.40] ABS direction in degrees".
This function can perform only when the software stroke limit is invalid. When the
software stroke limit is valid, the error "Illegal setting of ABS direction in unit of
degree" (error code: 546) occurs and positioning is not started.
To designate the movement direction in the ABS control, a "1" or "2" is written to the
"[Cd.40] ABS direction in degrees" of the buffer memory (initial value: 0).
The value written to the "[Cd.40] ABS direction in degrees" becomes valid only when
the positioning control is started.
In the continuous positioning control and continuous path control, the operation is
continued with the setting set at the time of start even if the setting is changed during
the operation.
The ABS movement direction in the unit
of degree is designated.
0: Shortcut (direction setting invalid)
1: ABS clockwise
2: ABS counterclockwise
45°
Function
9 - 19
Chapter 9 Major Positioning Control
2) Moved from 45° to 315°
315°
45°
Buffer memory address
QD77MS2
QD77MS16
QD77MS4
1550+100n
4350+100n
Initial
value
0