Storage item
Regenerative load
[Md.109]
ratio/Optional data
monitor output 1
Effective load
[Md.110]
torque/Optional data
monitor output 2
Peak torque
[Md.111]
ratio/Optional data
monitor output 3
Optional data monitor
[Md.112]
output 4
(2) Axis monitor data
Storage details/storage value
• The content set in "[Pr.91] Optional data monitor: Data type
setting 1" is stored at optional data monitor data type
setting.
• The regenerative load ratio is stored when nothing is set.
• The content set in "[Pr.92] Optional data monitor: Data type
setting 2" is stored at optional data monitor data type
setting.
• The effective load ratio is stored when nothing is set.
• The content set in "[Pr.93] Optional data monitor: Data type
setting 3" is stored at optional data monitor data type
setting.
• The peak torque ratio is stored when nothing is set.
• The content set in "[Pr.94] Optional data monitor: Data type
setting 4" is stored at optional data monitor data type
setting.
• "0" is stored when nothing is set.
POINT
When the communication interrupted by the servo amplifier's power supply OFF or
disconnection of communication cable with servo amplifiers during optional data
monitor, "0" is stored in [Md.109] to [Md.112].
14 - 55
Chapter 14 Common Functions
Buffer memory address
QD77MS2
QD77MS16
QD77MS4
878+100n
879+100n
880+100n
881+100n
n: Axis No.-1
2478+100n
2479+100n
2480+100n
2481+100n