Setting item
New acceleration
[Cd.10]
time value
New deceleration
[Cd.11]
time value
Acceleration/
deceleration time
change value
[Cd.12]
during speed
change,
enable/disable
: Refer to Section 5.7 "List of control data" for details on the setting details.
[QD77MS4 program example]
No.16 Acceleration/deceleration time change program
X34
531
M14
X0C
538
X35
557

[3] Setting the acceleration/deceleration time change function

To use the "acceleration/deceleration time change function", write the data
shown in the following table to the Simple Motion module using the sequence
program.
The set details are validated when a speed change is executed after the details
are written to the Simple Motion module.
Setting
value
Set the new acceleration time.
Set the new deceleration time.
Set "1: Acceleration/deceleration time
1
change enable".
Setting details
PLS
DMOV
K2000
DMOV
K0
MOVP
K1
TOP
H0
K1508
D15
MOVP
K0
13 - 56
Chapter 13 Control Sub Functions
Buffer memory address
QD77MS2
QD77MS4
1508+100n
1509+100n
1510+100n
1511+100n
1512+100n 4312+100n
<Pulsate acceleration/deceleration time change
M14
command>
<Set 2000ms for acceleration time>
D15
<Set 0 (not change) for deceleration time>
D17
D19
<Write acceleration/deceleration time>
K5
<Write acceleration/deceleration time change
enable>
U0\
G1512
<Write acceleration/deceleration time change
disable>
QD77MS16
4308+100n
4309+100n
4310+100n
4311+100n
n: Axis No.-1