Home Position Return Data - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Chapter 14 Common Functions

Home position return data

The following data saved at home position return completion to the buffer memory.
• Feed current value at home position return completion
• Servo command value at home position return completion
• Encoder position within one revolution of absolute position reference point data
• Encoder multiple revolution counter of absolute position reference point data
• Time 1 (Year: month) data
• Time 2 (Day: hour) data
• Time 3 (Minute: second) data
The data becomes valid only when the absolute system is set.
If the data has never been used in the absolute system in the incremental system setting,
"0" is output in all storage items.
14 - 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents