In the state of connecting between FR-A700 series and Simple Motion module, only
a part of parameters can be set if the parameter of the inverter "[Pr.77] Parameter
write selection" is in the initial state. Set "2: Write parameters during operation" to
rewrite the parameters of FR-A700 series.
Setting item
Reset selection/
disconnected PU
[Pr.75]
detection/
PU stop selection
(Note): Note that the default value is set to "14". (Change the value to "1 to 3".)
(3) Control of FR-A700 series parameters
Parameters set in FR-A700 series are not controlled by Simple Motion
module. Set the parameters by connecting FR-A700 series directly with the
operation panel on the front of inverter (FR-DU07/FR-PU07) or FR
Configurator that is inverter setup software. Confirm the instruction manual
of FR-A700 series for details of the setting items.
POINT
(4) Reset selection/disconnected PU detection/PU stop selection
When PU stop is executed in FR-A700 series, position error excessive, etc.
occur because a command from Simple Motion module does not stop. Set
"0 to 3" in the parameter of the inverter "[Pr.75] Reset selection/
disconnected PU detection/PU stop selection". To stop FR-A700 series, use
the stop signal and the forced stop of Simple Motion module, or use the
output stop (MRS) of FR-A700 series.
Default
Setting
value
value
• Reset input is always enabled.
0
• If the PU is disconnected, operation will be continued.
• PU stop is disabled at SSCNET
• A reset can be input only when the protective function is activated.
1
• If the PU is disconnected, operation will be continued.
• PU stop is disabled at SSCNET
• Reset input is always enabled.
2
• When the PU is disconnected, the inverter trips.
• PU stop is disabled at SSCNET
• A reset can be input only when the protective function is activated.
3
• When the PU is disconnected, the inverter trips.
• PU stop is disabled at SSCNET
14
• Reset input is always enabled.
14
• If the PU is disconnected, operation will be continued.
• Deceleration stop by PU stop in any operation mode.
• A reset can be input only when the protective function is activated.
15
• If the PU is disconnected, operation will be continued.
• Deceleration stop by PU stop in any operation mode.
• Reset input is always enabled.
16
• When the PU is disconnected, the inverter trips.
• Deceleration stop by PU stop in any operation mode.
• A reset can be input only when the protective function is activated.
17
• When the PU is disconnected, the inverter trips.
• Deceleration stop by PU stop in any operation mode.
Appendix - 74
Details
connection.
connection.
connection.
connection.
Appendices

Hide quick links: