STATUS
Field
Description
<Event Pulse
The incrementing number of detected pulses in the event input.
Count:>
Events which do not fulfil the requirements configured in CONFIGURE
Event Input are counted as an event pulse but not as an event. This is,
for example, the case when the time between two events is shorter than
defined in <Time Guard:>.
Counting starts as soon as the event input is configured and activated. To
reset the counter to 0, RESET (F5).
Next step
CONT (F1) exits STATUS Event Input.
c
c
a
a
b
0
GPS12_078
c
a
a
b
a) Event
b) Event pulse
c) Time guard
GPS1200