Leica GPS1200 Series Technical Reference Manual page 1102

Hide thumbs Also See for GPS1200 Series:
Table of Contents

Advertisement

Reference Plane
Step
Description
<Std Deviation:> Standard deviation of used points for plane defini-
tion. ----- is displayed unless more than four points are used to define
the plane.
<Max Δd:> Maximum distance between measured point and defined
plane. ----- is displayed unless more than four points are used to
define the plane.
6.
PAGE (F6) to change to the Points page.
7.
REFPLANE New Reference Plane, Points page
An * is shown to the right of the point for a point which will be used as
origin of the plane.
An is shown to the left of the point if the point is outside maximum
distance between a point and the calculated plane as defined in
REFPLANE Configuration, Parameters page.
The column Δd(m) displays the perpendicular distance of the point
from the definition of the plane.
ADD (F2) to add points from REFPLANE Data: Job Name to define
the reference plane.
USE (F3) to change between Yes and No for the highlighted point.
DEL (F4) to remove the highlighted point from the list.
SURVY (F5) to measure a point to be used for the plane.
DONE (F4) to return to REFPLANE New Reference Plane.