Leica GPS1200 Series Technical Reference Manual page 511

Hide thumbs Also See for GPS1200 Series:
Table of Contents

Advertisement

Requirements
Configuration of ASCII
Input interface step-by-
step
Config...\Interfaces... - General
The port and the device to be used for the gas analyser is configured correctly. The device
will most likely be RS232 using the same parameters as the depth sounder. Refer to "23.2
Accessing CONFIGURE Devices / CONFIGURE GPRS Internet Devices".
Step
Description
1.
Refer to "22.4.1 Overview" to access CONFIGURE ASCII Input.
2.
CONFIGURE ASCII Input
<Use Device: Yes>
<Port:> Select the port to which the depth sounder is connected.
<End of Msg: CR/LF>
3.
ANNOT (F2)
4.
CONFIGURE Annotations to be Used
<Annotation: Annotation 1>
<Accept ASCII: Yes>
<Message Desc: Gas 1>
<Message ID: GS1>
<Use Prefix: None>
<Send Reply: No>
5.
Still in CONFIGURE Annotations to be Used
<Annotation: Annotation 2>
<Accept ASCII: Yes>
<Message Desc: Gas 2>
GPS1200