Survey - Auto Points
Field
Option
<Monitor CQ:> Yes or No
<3D CQ Limit:> User input
<Beep When:> Logging
Not Logging
Never
GPS1200
Description
Activates monitoring of the coordinate quality. Auto
points are stored when the coordinate quality is within
the defined limit. For example, only phase fixed solu-
tions can be logged by defining a CQ limit.
Available for <Monitor CQ: Yes>.
Limit for the coordinate quality above which an auto
point is no longer automatically stored. When the CQ
of the auto point falls again below the defined value
then the storing of auto points begins again.
Instrument beeps when storing an auto point.
Available for <Monitor CQ: Yes>. Instrument gives a
single alarm beep each time an auto point is not
recorded because the limit for the coordinate quality
is exceeded. For <Log By: Time> the beep is given
at the time when the point should have been
recorded. Unless <Log By: Time>, the beep is given
at 1 Hz once the auto logging has stopped due to the
exceeded coordinate quality.
Instrument never beeps.
1196