Leica GPS1200 Series Technical Reference Manual page 402

Hide thumbs Also See for GPS1200 Series:
Table of Contents

Advertisement

Config...\Survey Settings...
CONFIGURE
Real-Time Stop Criteria
Description of fields
The parameters shown on this screen depend on the setting for <STOP Criteria:> in
CONFIGURE Point Occupation Settings.
Field
Option
<Pos Quality
User input
<:>
and
<Ht Quality <:>
<Positions:>
User input
GPS1200
CONT (F1)
To accept changes and to return to
CONFIGURE Point Occupation
Description
Sets the maximum position and height qualities for
each point occupation. Calculating the qualities starts
when OCUPY (F1) is pressed. The receiver stops
measuring when the position and height qualities are
both less than the configured values.
Raw data is logged for a minimum number of posi-
tions even when the <Pos Quality <:> and <Ht
Quality <:> is already less than the specified
maximum.
402
Settings.