Field
Option
<Time Slot:>
2, 3 or 4
The contents of the
choicelist depend
on the settings for
<Used Ref
Stations:>.
<End of
Nothing or CR
Message:>
<RTCM
2.1, 2.2 or 2.3
Version:>
Next step
PAGE (F6) changes to the NTRIP page.
GPS1200
Description
Available for <Time Slicing: Yes>.
The time slot represents the actual time delay. The
number of possible time slots is the number of refer-
ence stations in use. The time delay equals 1 s
divided by the total number of reference stations. If
two reference stations are used, the time delay is
0.50 s. Therefore, the time slots are at 0.00 s and at
0.50 s. With three reference stations, the time delay
is 0.33 s. The time slots are at 0.00, 0.33 and 0.66 s.
To add a Carriage Return at the end of the real-time
meassage.
Available for <R-Time Data: RTCM XX v2> in
CONFIGURE Real-Time Mode.
The same version must be used at the reference and
the rover.