Reference Line
OCUPY (F1)
To start measuring the point being staked. The
position mode icon changes to the static icon.
(F1) changes to STOP. The difference
between the current position and the point
being staked is still displayed.
STOP (F1)
To end measuring the point being staked.
When <Auto STOP: Yes> in CONFIGURE
Point Occupation Settings, recording of
positions ends automatically as defined by the
stop criteria. The position mode icon changes
to the moving icon. (F1) changes to STORE.
STORE (F1)
To store the measured point. When <Auto
STORE: Yes> in CONFIGURE Point Occu-
pation Settings, the measured point is stored
automatically. (F1) changes to OCUPY.
REVRS (F3)
To reverse the graphical display top to bottom.
A reversed graphical display can be used
when the point to be staked lies behind the
current position.
SURVY (F5)
To measure a point relative to the reference
line/arc.
PAGE (F6)
To change to another page on this screen.
GPS1200