DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
owner NAME
buckets NUM
interval SECONDS
Default
By default, this option is disabled.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
The RMON history group entry number is dynamic. Only the interface that is enabled for RMON
history statistics gathering will have a corresponding entry in the table. The configured interface
becomes the data source for the created entry.
Example
This example shows how to enable the RMON MIB history statistics group on Ethernet interface 3/0/8.
Switch# configure terminal
Switch(config)# interface eth3/0/8
Switch(config-if)# rmon collection history 101 owner it@domain.com interval 2000
Switch(config-if)#
57-3 rmon alarm
This command is used to configure an alarm entry to monitor an interface. Use the no form of this
command to remove an alarm entry.
rmon alarm INDEX VARIABLE INTERVAL {delta | absolute} rising-threshold VALUE [RISING-
EVENT-NUMBER] falling-threshold VALUE [FALLING-EVENT-NUMBER] [owner STRING]
no rmon alarm INDEX
Parameters
INDEX
VARIABLE
INTERVAL
delta
absolute
rising-threshold VALUE
RISING-EVENT-NUMBER
Specifies the owner string. The maximum length is 127.
Specifies the number of buckets specified for the RMON collection
history group of statistics. If not specified, the default is 50. The
range is from 1 to 65535.
Specifies the number of seconds in each polling cycle. The range is
from 1 to 3600.
Specifies the alarm index. The range is from 1 to 65535.
Specifies the object identifier of the variable to be sampled.
Specifies the interval in seconds for the sampling of the variable and
checking against the threshold. The valid range is from 1 to
2147483647.
Specifies that the delta of two consecutive sampled values is
monitored.
Specifies that the absolute sampled value is monitored.
Specifies the rising threshold. The valid range is from 0 to
2147483647.
(Optional) Specifies the index of the event entry that is used to
notify the rising threshold crossing event. The valid range is from 1
to 65535. If not specified, no action is taken while crossing the
513