DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
Use this command to create a static IPv6 neighbor cache entry on an interface. The static entry will be
either in the REACHABLE state, if the interface is UP, or in the INCOMPLETE state if the interface is
down. The reachable detection process will not be applied to the static entries.
The clear ipv6 neighbors command will clear the dynamic neighbor cache entries. Use the no ipv6
neighbor command to delete a static neighbor entry.
Example
This example shows how to create a static ipv6 neighbor cache entry.
Switch# configure terminal
Switch(config)# ipv6 neighbor fe80::1 vlan1 00-01-80-11-22-99
Switch(config)#
10-7 show ipv6 interface
This command is used to display IPv6 interface information.
show ipv6 interface [INTERFACE-ID] [brief]
Parameters
INTERFACE-ID
brief
Default
None.
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
Use this command to display IPv6 interface related configurations.
Example
This example shows how to display IPv6 interface information.
Switch# show ipv6 interface vlan2
vlan2 is up, Link status is down
IPv6 is enabled,
link-local address:
FE80::201:1FF:FE02:305
Global unicast address:
200::2/64 (DHCPv6 PD)
IP MTU is 1500 bytes
RA advertised retransmit interval is 0 milliseconds
Switch#
This example shows how to display brief IPv6 interface information.
(Optional) Specifies the interface for display.