D-Link DGS-1510 Series Reference Manual page 209

Gigabit ethernet smartpro switch
Hide thumbs Also See for DGS-1510 Series:
Table of Contents

Advertisement

DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid
for this configuration.
This command configures the TX power thresholds on the specified port. This value will be stored
both in the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then
written into the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is
just stored in the system and the displayed value will be the user-configured threshold. If there is no
user-configured threshold, the displayed value will always reflect the factory preset value defined by
the vendor.
The no form of this command has the effect to clear the configured threshold stored in system. It does
not change the threshold stored in the SFP/SFP+ transceivers. Use the no form of this command to
prevent threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Example
This example shows how to configure the TX power low warning threshold to 0.181 mW on interface
eth3/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring tx-power eth3/0/1 low warning mwatt 0.181
Switch(config)#
22-9 transceiver-monitoring voltage
This command is used to configure the threshold voltage of the specified port. Use the no form of this
command to remove the configuration.
transceiver-monitoring voltage INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring voltage INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE-ID
high
low
alarm
warning
VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Specifies the interface to modify.
Specifies that when the operating parameter rises above the
highest threshold, it indicates an abnormal status.
Specifies that when the operating parameter falls below this low
threshold value, it indicates an abnormal status.
Specifies to configure the high and low threshold value condition.
Specifies to configure the high and low warning threshold
conditions.
Specifies the threshold value. This value must be between 0 and
6.55 Volt.
206

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents