D-Link DGS-1510 Series Reference Manual page 24

Gigabit ethernet smartpro switch
Hide thumbs Also See for DGS-1510 Series:
Table of Contents

Advertisement

DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
Switch#show version
System MAC Address: 3C-1E-04-A1-CC-00
Unit ID
-------
1
Switch#
2-15 snmp-server enable traps environment
This command is used to enable the power, temperature and fan trap state.
snmp-server enable traps environment [fan] [power] [temperature]
no snmp-server enable traps environment [fan] [power] [temperature]
Parameters
fan
power
temperature
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command is used to configure the environment temperature threshold which corresponds to the
normal range of the temperature defined for the sensor. The low threshold must be smaller than the
high threshold. The configured range must fall within the operational range which corresponds to the
minimum and maximum allowed temperatures defined for the sensor. When the configured threshold
is crossed, a notification will be sent.
Example
This example shows how to configure the environment temperature thresholds for thermal sensor ID 1
on unit 1.
Switch# configure terminal
Switch(config)# environment temperature threshold unit 1 thermal 1 high 100 low 20
Switch(config)#
Module Name
------------------
DGS-1510-28XMP
(Optional) Specifies to enable the fan trap state for warning fan
event (fan failed or fan recover).
(Optional) Specifies to enable the power trap state for warning
power event (power failed or power recover).
(Optional) Specifies to enable the temperature trap state for warning
temperature event (temperature exceeds the thresholds or
temperature recover).
Versions
---------------------
H/W:A1
Bootloader:1.00.012
Runtime:1.30.003
21