Chrysler 2005 Crossfire SRT6 Service Manual page 969

Table of Contents

Advertisement

ZH
AMBIENT TEMPERATURE SENSOR CIRCUIT (CONTINUED)
7.
READ A/C HEATER CONTROL MODULE DTC'S WITH DRB III
Turn the ignition off.
Reconnect the Ambient Temperature Sensor connector.
Turn the ignition on.
With the DRB III , read A/C Heater Control Module DTC's.
Wait two minutes.
With the DRB III , read A/C Heater Control Module DTC's.
Does the DRB III display Ambient Temperature Sensor Failure
DTC?
Yes
>> Replace the Ambient Temperature Sensor. (Refer to 24 -
HEATING & AIR CONDITIONING/CONTROLS/AMBIENT
TEMP SENSOR - REMOVAL).
Perform BODY VERIFICATION TEST.
No
>> Go to 8
8.
READ A/C HEATER CONTROL MODULE DTC'S WITH DRB III
Ensure the Ambient Temperature Sensor is connected at this time.
Start the engine.
Turn the A/C system on and run for at least five minutes.
With the DRB III , read A/C Heater Control Module DTC's.
Does the DRB III display Ambient Temperature Sensor Failure
DTC?
Yes
>> Replace the Ambient Temperature Sensor. (Refer to 24 -
HEATING & AIR CONDITIONING/CONTROLS/AMBIENT
TEMP SENSOR - REMOVAL).
Perform BODY VERIFICATION TEST.
No
>> The condition that caused this DTC to set is currently not
present. Inspect the related wiring harness for a possible
intermittent condition.
Perform BODY VERIFICATION TEST.
INSTRUMENT CLUSTER - ELECTRICAL DIAGNOSTICS 8J - 15