Enabling Information Output To The Log Buffer - Huawei Quidway S3900 Series Operation Manual

Hide thumbs Also See for Quidway S3900 Series:
Table of Contents

Advertisement

Operation Manual – Information Center
Quidway S3900 Series Ethernet Switches-Release 1510
For example, to view log information of the switch on a monitor terminal, you need to
not only enable log information output to the monitor terminal, but also enable log
information terminal display function with the terminal logging command.
Perform the following configuration in user view.
Table 1-9 Enable debugging/log/trap terminal display
Operation
Enable
debugging/log/trap
information
terminal
function
Enable debugging
information
terminal
function
Enable
information
terminal
function
Enable
information
terminal
function

1.2.5 Enabling Information Output to the Log Buffer

Table 1-10 lists the related configurations on the switch.
Table 1-10 Enable information output to the log buffer
Operation
Enter system view
Enable
information center
Enable information
output to the log
buffer
Command
the
terminal monitor
display
terminal debugging
display
log
terminal logging
display
trap
terminal trapping
display
Command
system-view
the
info-center enable
info-center
[ channel { channel-number
| channel-name } | size
buffersize ]*
Huawei Technologies Proprietary
1-11
Chapter 1 Information Center
Description
Optional
By default, this function is enabled
for console user.
Optional
By default, debugging information
terminal display is disabled for
terminal users.
Optional
By default, log information terminal
display is enabled for console
users.
Optional
By default, trap information terminal
display is enabled for terminal
users.
Description
Optional
By default, the information
center is enabled.
Optional
logbuffer
By default, the switch uses
information
output log information to the
log buffer, which can holds up
to 512 items by default.
channel
4
to

Hide quick links: