Huawei Quidway S3900 Series Operation Manual page 55

Hide thumbs Also See for Quidway S3900 Series:
Table of Contents

Advertisement

Operation Manual – Login
Quidway S3900 Series Ethernet Switches-Release 1510
Operation
Set the timeout time for
the user interface
Note that the command level available to users logging into a switch depends on the
service-type terminal [ level level ] command, as listed in Table 2-9.
Table 2-9 Determine the command level
Authentication
mode
authentication
-mode scheme
[ command-au
thorization ]
2.6.2 Configuration Example
I. Network requirements
Assume that you are a level 3 VTY user and want to perform the following configuration
for users logging in through the Console port:
Configure the name of the local user to be "guest".
Set the authentication password of the local user to 123456 (in plain text).
Set the service type of the local user to Terminal.
Configure to authenticate users logging in through the Console port in the scheme
mode.
Command
idle-timeout minutes
[ seconds ]
Scenario
User type
The service-type terminal
Users
command does not specify
logging into
the
available
the Console
level.
port
and
pass
AAA&RADI
US or local
The service-type terminal
authenticati
command
on
available command level.
Huawei Technologies Proprietary
2-15
Chapter 2 Logging in through the Console Port
Description
Optional
The default timeout time of a
user interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a
user interface is terminated if no
operation is performed in the
user interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.
Command
command
specifies
the
Command level
Level 0
The
default
command level of
local users is level
0.
Determined by the
command
level
specified by the
service-type
terminal
command