Huawei Quidway S3900 Series Operation Manual page 57

Hide thumbs Also See for Quidway S3900 Series:
Table of Contents

Advertisement

Operation Manual – Login
Quidway S3900 Series Ethernet Switches-Release 1510
[Quidway-ui-aux0] user privilege level 2
# Set the baud rate of the Console port to 19,200 bps.
[Quidway-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[Quidway-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store to 20.
[Quidway-ui-aux0] history-command max-size 20
# Set the timeout time of the AUX user interface to 6 minutes.
[Quidway-ui-aux0] idle-timeout 6