Huawei Quidway S3900 Series Operation Manual page 65

Hide thumbs Also See for Quidway S3900 Series:
Table of Contents

Advertisement

Operation Manual – Login
Quidway S3900 Series Ethernet Switches-Release 1510
Operation
Set
the
time of the user
interface
Note that if you configure to authenticate the users in the password mode, the
command level available to users logging into a switch depends on both the
authentication-mode password command and the user privilege level level
command, as listed in Table 3-7.
Table 3-7 Determine the command level when users logging into switches are
authenticated in the password mode
Authentication
mode
Password
(authentication-
mode
password)
3.3.2 Configuration Example
I. Network requirements
Assume that you are a level 3 AUX user and want to perform the following configuration
for Telnet users logging into VTY 0:
Authenticate users logging into VTY 0 using the local password.
Set the local password to 123456 (in plain text).
Commands of level 2 are available to users logging into VTY 0.
Telnet protocol is supported.
The screen can contain up to 30 lines.
The history command buffer can contain up to 20 commands.
The timeout time of VTY 0 is 6 minutes.
Command
timeout
idle-timeout
[ seconds ]
Scenario
User type
VTY users
Huawei Technologies Proprietary
3-8
Chapter 3 Logging in through Telnet
Optional
The default timeout time of a
user interface is 10 minutes.
With the timeout time being
10 minutes, the connection to
minutes
a user interface is terminated
if no operation is performed in
the user interface within 10
minutes.
You can use the idle-timeout
0 command to disable the
timeout function.
Command
The user privilege level level
command not executed
The user privilege level level
command already executed
Description
Command
level
Level 0
Determined
by the level
argument