Table 21 Error codes (part code 0605) (continued)
Part
Error
Code
Number
0605
68802
0605
68871
0605
68884
0605
68901
0605
68902
0605
68903
0605
78031
0605
78032
0605
78047

Part code 00622

Table 22 Error codes (part code 00622)
Part
Error
Code
Number
00622
105009
00622
105040
00622
105042
00622
105084
00622
105204
48
Message (part code group 0nnn)
Error Message
The volume to be maintained includes
the system disk being used at Audit Log.
The specified volumes include remote
command devices being used with
mirrors in the Journal of the Continuous
Access Journal or the Continuous Access
Journal Z.
Quorum disks are included in the items
to be maintained.
An external volume was not able to be
recovered.
The external volume was able to be
restored, but some of mapping paths
were not able to be restored normally.
Failed to disconnect from the external
volume.
The specified Processor Blade is blocked.
The specified Processor Blade is not
mounted.
A sufficient Cache Control Device cannot
be allocated to the target volume.
Error Message
All the check boxes are cleared.
[Detail] is clicked without selecting any
row.
[Delete] is clicked without selecting any
row.
The setting cannot be changed, because
an invalid value has been input.
A necessary program product is not
installed, or insufficient permissions to
execute editorial operation.
Recommended Action
Set the Audit Log buffer function to
"Disable," then retry the operation.
Release the allocation of mirrors in the
Journal for the remote command device,
then retry the operation.
Release the quorum disks, then retry the
operation.
Check the status of the mapping path
and resolve the root cause of blockade,
then retry the operation.
Check the status of the mapping path
and resolve the root cause of blockade
if needed, then retry the operation.
Check the states of the external volume
and the mapping path, and do not retry
the operation until the states return to
normal.
If the states cannot be restored to normal,
or if the problem persists despite retrying,
please contact HP Technical Support.
Recover the blocked Processor Blade,
then specify it.
Check the specified Processor Blade.
Delete unnecessary volumes, then retry
the operation. If this problem persists,
please contact HP Technical Support.
Recommended Action
Check the check boxes for the items that
you want to change, then retry the
operation.
Select one or more table rows.
Select one or more table rows.
Check the setting(s).
Install a necessary program product.
Otherwise, execute the operation with
the user ID who has a permission to
execute editorial operation, or permit the
user to enable the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
Severity
Level
W
W
W
W
W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Table of Contents