Table 52 Error codes (part code 6010) (continued)
Part
Error
Code
Number
6010
9308
6010
9309
6010
9310
6010
931 1
6010
9316
6010
9317
6010
9318
6010
9324
6010
9325
6010
9327
6010
9332
6010
9337
6010
9360
6010
55035
6010
55202
6010
55203
162 Message (part code group 6nnn)
Error Message
You set the same path more than once.
The duplicate paths are excluded.
All paths which you set have already
been registered. This operation will
terminate because there is no path which
can be added.
You set the same SSID more than once.
Duplicate SSIDs are excluded.
All SSIDs which you set have already
been registered. This operation will
terminate because there is no SSID which
can be added.
Through this operation, M-VOL status will
be changed to Simplex mode even if the
M-VOL is online to the host.
The destination volume of the specified
volume pair may contain some
inconsistency because volume copy is
not completed yet. Full volume
initialization is required before re-using
it.
As a result of this operation, you will not
be able to re-start ERASE R-VOL
operation.
The specified operation is prohibited
while the script is running.
The script is terminated forcibly.
The monitoring time is over, but the
history file is not fully updated yet.
This operation is not applied yet.
The requested operation has started.
The specified value exceeds the range.
Alternatively, the relationship between
the specified values is not appropriate.
If you plan to create a pair with the
specified LUSE volumes, a DKC path is
required.
The subsystem specified by Controller ID
is not available for the particular CU
selected from the tree.
There are no initiator ports that can be
used by the subsystem specified by
Controller ID.
Recommended Action
Since there were overlapped paths in
the added paths, the overlapped paths
were eliminated. Click [OK] and
continue.
Since all the added paths overlapped,
the operation of adding paths cannot be
executed. Click [OK] and continue.
Since there were overlapped SSIDs in
the added SSIDs, the overlapped SSIDs
were eliminated. Click [OK], and
continue.
Since all the added SSIDs are
overlapped, the operation of adding
SSIDs cannot be executed. Click [OK],
and continue.
Follow the instructions in the message.
Follow the instructions in the message.
To delete the pair, even though you
cannot re-execute the R-VOL deletion,
click [OK]. If not, click [Cancel].
Try again after the script ends.
Click [OK].
Click [Refresh] to update the history file.
If this problem persists, please contact
HP Technical Support.
Click [OK], then continue the operation.
The requested operation has started.
Click [OK] to close the dialog.
Check the specified values and retry the
operation.
Select "Add RCU" command, then
register a DKC path.
Find the CUs that can be used by the
storage system specified by the
Controller ID.
Find the ports that can be used by the
storage system specified by the
Controller ID, and set them as initiator
ports.
Severity
Level
W
W
W
W
W
i
i
W
i
i
i
i
W
W
W
W