Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58694
6505
58695
6505
58696
6505
58697
6505
58698
6505
58699
6505
58700
6505
58701
6505
58702
6505
58703
192 Message (part code group 6nnn)
Error Message
The Delta resync operation failed. Check
the status of the secondary data volume,
or the status of the connected
communication line.
No more journals can be allocated to
the specified command device.
Delete the journals registered in the
extended consistency group (EXCTG),
then retry the operation with another
command device.
The specified volume cannot be used as
a journal volume because the volume is
an external volume to which the I/O
suppression mode is enabled.
The journal volume cannot be deleted
from the specified journal due to the
mirror status.
The operation failed because the
specified secondary data volume was
used by Delta resync.
The operation to change the status to the
status ready for Delta resync failed
because the specified secondary data
volume was used by one of the following
program products.
Business Copy/Snapshot
Business Copy Z
Compatible FlashCopy
The operation to change the status to the
status ready for Delta resync failed.
The specified secondary data volume
should meet the following requirements.
The specified volume is a secondary
data volume of another mirror.
The pair status of the specified volume
is PAIR or Duplex.
The Delta resync operation failed,
because journal data of the master
journal were insufficient.
The Delta resync operation failed,
because the number of pairs for each
mirror of the restore journal was
different.
The Delta resync operation failed
because the secondary data volume was
updated.
Recommended Action
Check the status of the secondary data
volume, or the status of the connected
communication line. When no
abnormality is found in the status of the
secondary data volume or the
communication line, please contact HP
Technical Support.
Delete the journal registered in the
extended consistency group (EXCTG),
then retry the operation with another
command device.
Check the I/O suppression mode of the
specified volume.
Check the mirror status of the specified
journal.
Check the status of the secondary data
volume.
Check the status of the specified
secondary data volume in the Business
Copy/Snapshot window, the Business
Copy Z window, or the Compatible
FlashCopy window.
Check the status of the specified
secondary data volume.
Delta resync cannot be executed. Delete
the pair ready for Delta resync and copy
all data in the primary data volume.
Check the number of pairs for each
mirror of the restore journal.
Delta resync cannot be executed. Delete
the pair ready for Delta resync and copy
all data in the primary data volume.
Severity
Level
W
W
W
W
W
W
W
W
W
W