Table 59 Error codes (part code 7005) (continued)
Part
Error
Error Message
Code
Number
7005
8654
Boot device and S-VOL do not match in
Paircreate, Pairresync, or Pairsplit-S
instructions.
7005
8655
An invalid secondary SSID is specified
for the Paircreate or Pairresync
command.
7005
8656
The secondary SSID specified for the
pairsplit-S or pairsplit command is
invalid.
7005
8657
The Swap&Freeze option cannot be
specified, because the mode 80 is on.
7005
8670
The number of volumes composing the
LUSE volume specified as the P-VOL does
not match the number of volumes
composing the LUSE volume specified as
the S-VOL.
7005
8695
The specified MU number is not less than
or equal to 2.
7005
8920
Because a L1 pair is not PSUS, you
cannot operate to L2.
7005
55264
The command was rejected, because
you tried to create a volume pair formed
with a volume to which VMA is set by
Data Retention and a volume without
VMA.
7005
55301
You cannot create the pair, because the
licensed capacity of Open System Array
Management is insufficient.
7005
55645
Quick Restore cannot be executed
because the specified pair is composed
of the external volumes with different
cache mode settings.
7005
56301
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
7005
56302
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
7005
56303
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
7005
56524
This function cannot be used by the
storage partition administrator.
7005
57101
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
Recommended Action
Check the target volume number.
Check the contents, and retry.
Check the contents, and retry.
Please contact HP Technical Support.
Match the number of volumes composing
the LUSE volume you intend to specify
as the P-VOL and the number of volumes
composing the LUSE volume you intend
to specify as the S-VOL, then retry the
operation.
Correct the MU number, then retry the
operation.
Wait until L1 pair becomes PSUS status,
and execute the operation to L2 pair.
You cannot create a pair using these
volumes.
If you want to create a pair by using a
volume without VMA, you must only use
volumes without VMA. If you want to
create a pair by using a volume with
VMA, you must only use volumes with
VMA.
Increase the licensed capacity of Open
System Array Management, then retry
the operation.
Use the Reverse Resync option.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Please contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Severity
Level
W
W
W
E
W
W
W
W
W
W
E
E
E
E
E
Part code 7005 231