HP StorageWorks P9000 - Disk Arrays Manual page 247

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 62 Error codes (part code 7105) (continued)
Part
Error
Error Message
Code
Number
7105
8609
The specified volume is not set as a
reserved volume.
7105
8610
The T-VOL is a target volume for Auto
LUN.
7105
861 1
The specified volume is a T-VOL.
7105
8612
The specified volume is not a T-VOL.
7105
8613
The RAID level of the specified T-VOL is
not supported.
7105
8614
The command has been rejected,
because the specified T-VOL is used as
M-VOL of Continuous Access
Synchronous Z pair.
7105
8615
The command has been rejected,
because the specified T-VOL is used as
R-VOL of Continuous Access Synchronous
Z pair.
7105
8618
The T-VOL is already defined as an
S-VOL.
7105
8619
The specified T-VOL is defined as a
source volume for Auto LUN.
7105
8622
The command has been rejected,
because the specified volume is used as
M-VOL of Continuous Access
Synchronous Z pair.
7105
8623
The command has been rejected,
because the specified volume is used as
R-VOL of Continuous Access Synchronous
Z pair.
7105
8624
The command has been rejected,
because there is no pair to be operated.
7105
8625
The P-VOL(S-VOL) and S-VOL(T-VOL)
have the same number.
7105
8626
The Simplex command was rejected,
because the high-speed Split was in
progress.
7105
8627
The Pairresync operation has been
rejected, because pair status is SP-Pend.
7105
8628
An internal logic contradition occurred.
7105
8629
The status mode specification is invalid.
7105
8630
The status mode type is invalid.
Recommended Action
Check the status of the volume.
Release the Auto LUN setting.
Check the status of the volume.
Check the status of the volume.
Specify a volume of the supported RAID
level.
The requested command cannot be
executed in the current status of
Continuous Access Synchronous Z pair.
See the section "Sharing Business Copy
for Mainframe volumes" in the Business
Copy for Mainframe Systems User Guide
for the relation between the state of
Continuous Access Synchronous Z pair
and the Business Copy Z operations.
The R-VOL of Continuous Access
Synchronous Z pair cannot be used as
T-VOL of Business Copy Z.
Specify another volume.
Check the volume number.
Release the Auto LUN setting.
The P-VOL of Continuous Access
Synchronous Z pair cannot be used as
a reserved volume.
Specify another volume.
The R-VOL of Continuous Access
Synchronous Z pair cannot be used as
a reserved volume.
Specify another volume.
Confirm whether the volumes specified
for S-VOL and T-VOL are correct or not.
Check the specified volume number.
After the high-speed Split is completed,
retry the operation.
Wait until the status of the pair changes
to Split.
Select other pairs.
Check the contents, and retry.
Check the contents, and retry.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
E
W
W
Part code 7105 247

Advertisement