Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8745
A volume cannot be used as an R-VOL
when:
it is used by Compatible XRC.
it is used by PPRC or Remote Copy.
it is used by Concurrent Copy.
it is in a reserved condition.
it is used by Continuous Access
Journal or Continuous Access Journal
Z.
it is used by Business Copy Z or
Compatible FlashCopy.
6005
8746
The device emulation type of the M-VOL
is not supported.
6005
8747
Current microcode version does not
support the specified operation.
6005
8748
Specified M-VOL may be in use by
HOST.
6005
8749
Specified R-VOL is still online from
HOST.
6005
8751
Remote Copy is not supported under the
RCU controller emulation type.
6005
8753
An internal error occurred.
6005
8754
Invalid MCU serial number or MCU
SSID.
6005
8755
The serial number, SSID or CU number
of the RCU is invalid.
6005
8756
MCU disk array cache is not active.
6005
8757
One side of the Cache or shared
memory on the MCU is blocked.
6005
8758
Unexpected error on MCU.
6005
8759
RCU Subsystem Cache status is not
active.
Recommended Action
Select another volume.
See the INSTALLATION SECTION and
OPENPLATFORM SECTION in the
maintenance manual to confirm whether
the device emulation type of the M-VOL
is supported by Remote Copy.
The version of the microcode on the
9900 storage system does not support
the specified function or operation.
Please contact HP Technical Support.
Data migration cannot start because the
volume is online. Vary the path offline,
and retry.
Check if the input number of R-VOL is
correct. If not, enter the correct R-VOL
number. If the number is correct, vary
the specified path offline.
Confirm the RCU controller emulation
type.
Please contact HP Technical Support.
Check the serial number or SSID of
MCU, then retry with correct parameter.
Check the serial number, SSID or CU
number of the RCU, and retry the
operation with correct parameters.
Check the connection LCP ports of the
RCU. Connect the path correctly, and
retry the operation
Check the storage system cache status
of the MCU from the host. If it is off, set
it on and retry. If it cannot be set on,
please contact HP Technical Support.
There is an invalid cache or shared
memory status on the MCU. Check the
status and recover the cache or shared
memory, then retry the operation.
Please contact HP Technical Support.
Please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
E
W
W
W
E
E
W
Part code 6005 139