Part Code 7007; Part Code 7010 - HP StorageWorks P9000 - Disk Arrays Manual

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 59 Error codes (part code 7005) (continued)
Part
Error
Code
Number
7005
75004
7005
75005
7005
75006
7005
75007
7005
78053
7005
78054
7005
78055

Part code 7007

Table 60 Error codes (part code 7007)
Part
Error
Code
Number
7007
6012
7007
71 1 1

Part code 7010

Table 61 Error codes (part code 7010)
Part
Error
Code
Number
7010
51 15
7010
51 16
7010
51 17
238 Message (part code group 7nnn)
Error Message
The command was rejected, because the
Thin Provisioning volume specified as a
reserved volume was not associated with
a pool.
The command was rejected, because no
LU path was set to the volume specified
as P-VOL.
The command was rejected, because no
LU path was set to the volume specified
as S-VOL.
The command was rejected, because no
LU path was set to the volume specified
as a reserved VOL.
The operation failed, because the current
microcode version does not support the
capacity of the specified P-VOL.
The operation failed, because the current
microcode version does not support the
capacity of the specified S-VOL.
The operation failed, because the current
microcode version does not support the
capacity of the specified reserved
volume.
Error Message
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
Error Message
The volume of S-VOL is different from
specified P-VOL.
You cannot create another L1 pair,
because the number of L1 pairs exceeds
the maximum.
No MU number is available.
Recommended Action
Associate the specified Thin Provisioning
volume with a pool, then retry the
operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Recommended Action
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Recommended Action
Check the capacity of P-VOL and S-VOL.
Specify a volume with the same capacity,
and retry the operation.
You cannot create L1 pair for the
specified P-VOL. Delete the created L1
pair, and retry the operation.
You cannot create the specified pair.
Check the possible number of pairs to
be created.
Severity
Level
W
W
W
W
W
W
W
Severity
Level
E
E
Severity
Level
W
W
W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Table of Contents