Table 52 Error codes (part code 6010) (continued)
Part
Error
Error Message
Code
Number
6010
55204
The M-VOL or R-VOL is not supported by
the specified RCU.
6010
56537
There are no consistency groups
available for the CLPR of the specified
volumes. Please register the consistency
groups and then retry the operation.
6010
56540
The size of the specified file exceeds 8
megabytes, so the file cannot be
uploaded.
6010
59001
Are you sure you want to cancel the
change operation of the option
parameter that you specified?
6010
5901 1
Are you sure you want to output the %s
file?
6010
59012
The %s file does not exist.
6010
59013
The specified file already exists. Do you
want to overwrite this file?
6010
59026
The specified RCU has been already set.
Check the RCU parameter settings.
6010
59030
The monitoring data saved at present
will be deleted.
6010
59031
The monitoring data saved at present
will be deleted when the monitoring
switch is set to Enable the next time.
6010
59340
[Warning]
This operation deletes all command
devices for the Business Continuity
Manager. Are you sure you want to
continue this operation?
6010
65663
The specified LDKC number is incorrect.
Specify the correct LDKC number.
6010
65664
The specified volume is not valid for this
program product. Specify another
volume.
6010
65665
The specified volume is not the volume
to be monitored. Check the monitoring
setting.
6010
65769
There are no quorum disk IDs available.
Register some quorum disk IDs, then retry
the operation.
Recommended Action
Check the settings of the specified RCU,
M-VOL and R-VOL.
Register the consistency groups, then
retry the operation.
Check the size of the file, decrease the
size and retry the operation.
To cancel the change operation of the
option parameter, click [OK]. Otherwise,
click [Cancel].
To output the file, click [Yes]. Otherwise,
click [No].
Click [OK].
To overwrite the file, click [Yes].
Otherwise, click [No].
Check the RCU parameter settings.
To continue the operation, click [OK]. To
cancel the operation, click [Cancel].
The monitoring data currently saved will
be deleted if you change the setting of
the monitoring switch. If necessary, use
the Performance Monitor Export Tool to
export the monitoring data file.
To continue processing, click [OK]. To
stop processing, click [Cancel].
The monitoring data currently saved will
be deleted when you change the setting
of the monitoring switch. If necessary,
use the Export Tool to save the
monitoring data.
To continue the operation, click [OK].
Otherwise, click [Cancel].
Specify the correct LDKC number.
Specify another volume.
Check the monitoring setting.
Register some quorum disk IDs, then retry
the operation.
Severity
Level
W
W
W
W
i
i
W
W
W
i
W
W
W
W
W
Part code 6010 163