Table 48 Error codes (part code 5305) (continued)
Part
Error
Code
Number
5305
8971
5305
55500
5305
56301
5305
56302
5305
56303
5305
56524
5305
56525
5305
56526
5305
57101
132 Message (part code group 5nnn)
Error Message
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
This function cannot be used by the
storage partition administrator.
Because the settings across the multiple
SLPRs are contained, the authority has
been shifted to the storage administrator
from the storage partition administrator.
To continue the operation, please contact
the storage administrator. To perform
other operations, select a function button.
The resources of other SLPR(s) cannot be
accessed.
An error occurred during SVP
processing.
Recommended Action
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
The error may be caused by a temporary
communication failure. Reboot the SVP
or click [Refresh All] on the File menu of
Remote Web Console and refresh the
configuration information to recover from
the error.
If this problem persists, please contact
HP Technical Support.
The error may be caused by a temporary
communication failure. Reboot the SVP
or click [Refresh All] on the File menu of
Remote Web Console and refresh the
configuration information to recover from
the error.
If this problem persists, please contact
HP Technical Support.
The error may be caused by a temporary
communication failure. Reboot the SVP
or click [Refresh All] on the File menu of
Remote Web Console and refresh the
configuration information to recover from
the error.
If this problem persists, please contact
HP Technical Support.
Select another window. If you want to
set this function, please contact the
storage administrator.
To continue the operation, please contact
the storage administrator and have the
settings across the multiple SLPRs
cancelled, then retry the operation.
To perform other operations, please
select a function button.
Correct the settings, then retry the
operation.
The error may be caused by a temporary
communication failure. Reboot the SVP
or click [Refresh All] on the File menu of
Remote Web Console and refresh the
configuration information to recover from
the error.
If this problem persists, please contact
HP Technical Support.
Severity
Level
E
E
E
E
E
E
E
E
E